The radio has a touch screen, making the user interface quite intuitive. Touching the Model Setup (Airplane icon), Configure Screens (Multiple Screens icon), and System Setup (Gear icon) tabs take you directly to those functions, which are described in those sections of the manual. They can also be accessed using the [MDL], [DISP] and [SYS] keys respectively.
Alternately the rotary selector may be used to move the highlight to the desired tile or parameter, followed by pressing Enter to select it.
A long press on the [RTN] key will return you to the Home screen from any sub-menu.
Touching the system time on the right of the bottom bar takes you to the Date & Time section, allowing you to set the time and date.
Touching the speaker or battery icons in the top bar will bring up the relevant Sound & Vibr. and Battery control panels.
A long press on the [ENT] key from the Home screens brings up a reset menu:
Reset flight will reset telemetry, the timers, and the function switches. Note that preflight checks will be done after a ‘Reset flight’.
Will reset the telemetry.
Will reset the timers.
The LCD touchscreen may be locked to prevent inadvertent operation by pressing [ENTER] and [PAGE] simultaneously for 1 second from the Home screen. It is also available as a special function.
Ethos provides a virtual keyboard for editing text fields.
Simply touch on any text field (or click [ENT]) to bring up the keyboard.
Touch the '?123' or 'abc' key to toggle between alpha and numeric keypads. There is also a caps lock for entering uppercase letters.
When touching a number value a dialog appears at the bottom of the screen with the number value controls:
The ‘More’ button on the right opens another dialog for additional options:
The slider allows for the value to be adjusted quickly. The rotary encoder can also be used.
To revert back to the number adjustment keys, select ‘Disable slider.
Another example is a telemetry range value, which can be edited in a similar way.
Ethos has a very powerful 'Options' feature. Almost anywhere a value or source is expected, a long press of the Enter key will bring up an options dialog.
Fields with this feature can be identified by the menu icon (hamburger symbol) in the top left corner of the field.
The value options dialog shows which parameter is being configured. In this example, you have the choice of setting the weight/rates to maximum or minimum, or to use a source. Using a source like a pot would allow the weight/rates to be adjusted in flight.
If you long press Enter on a value field that has already been changed to use a source, a dialog pops up allowing you to convert the source's current value to a fixed value.
Clicking on 'Options' will bring up options for the source, see below.
Source options
Invert
Invert allows a source such as a switch position to be negated or inverted. For
example instead of being active when switch SA is up, it would be active when switch SA is NOT up, i.e. in either the mid or down positions.
Edge
You can select the 'Edge' option if you need a one-time action when the source
transitions from False to True or from True to False. Only the transition is acted upon, not the True or False state.
Please note that the ‘Edge’ option is available on switches but depending on the context.
Half range
The ‘Half range’ option is available when using a 2-POS Switch or logic switch as a source. The range becomes [0-100%] instead of [-100%-100%].
Source option for trims
By default, trims have a range of +/- 25%. When used as a source, trims can optionally be changed to full range +/- 100% (long press Enter on the trim).
Ignore trainer input
In logic switches the sources may have this option set to ignore sources coming from the trainer input. A typical application is where a logic switch is configured to detect movement of the master trainer’s sticks (e.g. Elevator stick) to allow for instant
intervention if things go wrong. This option is needed to prevent the student stick inputs from triggering the logic switch.
Var options
Negative
Enabling Negative will make the Var value negative in this instance.
Ignore range
Some parameters have asymmetric ranges, such as the Min/Max parameters in
Outputs, which have ranges of (-150% to 0%) and (0% to +150%) respectively.
When using VARs as a source to adjust the Min/Max parameters, unless the Var has an
identical range, it will be necessary to set the Var range to be ignored to avoid unexpected values due to range conversion.
Sensor options
On a telemetry source, the options dialog allows the sensor to be inverted, or its